The ACE Encore series Li-ion UPS batteries are developed for rack mounted. This series integrates ACE high energy density and high-rate cells with dedicated battery management system (BMS) to provide system reliability and improved performance. This series is designed as a perfect match for power backup of data centers and offices, especially under high-rate discharge circumstances.
Voltage, current, temperature, SOH, SOC real-time detection | Specially designed for three wire and two wire UPS system application | Dual redundancy of auxiliary source reduces the risk of AC power interruption |
BMS control and protection double redundancy: contactor control, shunt trip of MCCB | Support wide DC voltage range configuration, compatible with UPS of high and low voltage platform | Directional explosion-proof valve design, which can effectively avoid cell failure and ensure high safety |
Integrated with fully-automatically produced LFP prismatic 50 Ah cells, ensuring excellent consistency and life span | Short circuit protection double redundancy: circuit breaker protection, molded case circuit breaker magnetic tripping | Comprehensive thermal simulation and testing to ensure the safety of each cell in the case of large current discharge |
Data centers
Distributed data centers
Bank data centers
Project | Item | Cell | Module | System(Module 8/9/10/11/12) | ||||
Basic ParameterBasic Parameters | Configure | / | 2P16S | 2P128S | 2P144S | 2P160S | 2P176S | 2P192S |
Rated Voltage(V) | 3.2 | 51.2 | 410 | 461 | 512 | 563 | 614 | |
Voltage Range(V) | 2.5-3.6 | 40-57.6 | 320-461 | 360-518 | 400-576 | 400-634 | 480-691 | |
Rated Capacity(Ah) | 50 | 100 | 100 | |||||
Rated Energy (KWh) | 0.16 | 5.12 | 41 | 46.1 | 51.2 | 56.3 | 61.4 | |
Max Power(KW) | 0.8 | 25.6 | 205 | 230.5 | 256 | 281.5 | 307 | |
Size (Min) | 26*148*129 W*D*H |
438*600*130 W*D*H |
600*800*2000 W*D*H |
|||||
Weight(Kg) | 1.12 | 50 | 600 | 650 | 700 | 750 | 800 | |
Performance Parameters | Cell Chemistry System | LFP | ||||||
Charging Current | 1C (100A) max, suggest 30A | |||||||
Discharge Power (based on standard 10 module configuration) |
10min: 205KW 15min: 180KW |
|||||||
Discharge Cut Off Voltage | Cell: 2.3V System: 408V (cell: 2.55V) |
|||||||
Charging Cut Off Voltage | Cell: 3.6V System: 568V (cell: 2.55V) |
|||||||
certification | Cell: UL1973 / IEC62619 / UL9540A System: IEC62619 / UL1973 / UL9540A / IEC62477-1 / IEC61000-6-2&4 |
|||||||
Function Parameters | Support UPS DC Line System | Two-line system / Three line system | ||||||
Communication Mode | CANUBS; RS485 | |||||||
Auto Star | When the power grid is restored, the battery system will start automatically | |||||||
Black Star | When the power grid is cut off, the battery system supports the first start-up | |||||||
Environmental Parameters | Core Algorithm And Control | Power prediction / Calculation of remaining standby time / Exit of single fault cabinet | ||||||
Working Environment Temperature | 0-40°C, Recommended temperature 25±5°C | |||||||
Working Environment Humidity | ≦95%RH; non-condensing | |||||||
Altitude | ≦2000m No reduction; Max support 4000m |
The ACE Encore series Li-ion UPS batteries are developed for rack mounted. This series integrates ACE high energy density and high-rate cells with dedicated battery management system (BMS) to provide system reliability and improved performance. This series is designed as a perfect match for power backup of data centers and offices, especially under high-rate discharge circumstances.
Voltage, current, temperature, SOH, SOC real-time detection | Specially designed for three wire and two wire UPS system application | Dual redundancy of auxiliary source reduces the risk of AC power interruption |
BMS control and protection double redundancy: contactor control, shunt trip of MCCB | Support wide DC voltage range configuration, compatible with UPS of high and low voltage platform | Directional explosion-proof valve design, which can effectively avoid cell failure and ensure high safety |
Integrated with fully-automatically produced LFP prismatic 50 Ah cells, ensuring excellent consistency and life span | Short circuit protection double redundancy: circuit breaker protection, molded case circuit breaker magnetic tripping | Comprehensive thermal simulation and testing to ensure the safety of each cell in the case of large current discharge |
Data centers
Distributed data centers
Bank data centers
Project | Item | Cell | Module | System(Module 8/9/10/11/12) | ||||
Basic ParameterBasic Parameters | Configure | / | 2P16S | 2P128S | 2P144S | 2P160S | 2P176S | 2P192S |
Rated Voltage(V) | 3.2 | 51.2 | 410 | 461 | 512 | 563 | 614 | |
Voltage Range(V) | 2.5-3.6 | 40-57.6 | 320-461 | 360-518 | 400-576 | 400-634 | 480-691 | |
Rated Capacity(Ah) | 50 | 100 | 100 | |||||
Rated Energy (KWh) | 0.16 | 5.12 | 41 | 46.1 | 51.2 | 56.3 | 61.4 | |
Max Power(KW) | 0.8 | 25.6 | 205 | 230.5 | 256 | 281.5 | 307 | |
Size (Min) | 26*148*129 W*D*H |
438*600*130 W*D*H |
600*800*2000 W*D*H |
|||||
Weight(Kg) | 1.12 | 50 | 600 | 650 | 700 | 750 | 800 | |
Performance Parameters | Cell Chemistry System | LFP | ||||||
Charging Current | 1C (100A) max, suggest 30A | |||||||
Discharge Power (based on standard 10 module configuration) |
10min: 205KW 15min: 180KW |
|||||||
Discharge Cut Off Voltage | Cell: 2.3V System: 408V (cell: 2.55V) |
|||||||
Charging Cut Off Voltage | Cell: 3.6V System: 568V (cell: 2.55V) |
|||||||
certification | Cell: UL1973 / IEC62619 / UL9540A System: IEC62619 / UL1973 / UL9540A / IEC62477-1 / IEC61000-6-2&4 |
|||||||
Function Parameters | Support UPS DC Line System | Two-line system / Three line system | ||||||
Communication Mode | CANUBS; RS485 | |||||||
Auto Star | When the power grid is restored, the battery system will start automatically | |||||||
Black Star | When the power grid is cut off, the battery system supports the first start-up | |||||||
Environmental Parameters | Core Algorithm And Control | Power prediction / Calculation of remaining standby time / Exit of single fault cabinet | ||||||
Working Environment Temperature | 0-40°C, Recommended temperature 25±5°C | |||||||
Working Environment Humidity | ≦95%RH; non-condensing | |||||||
Altitude | ≦2000m No reduction; Max support 4000m |
Lithium-ion UPS 512V Battery Solutions